Corbels - Secondary reinforcement following EC-2 (1992-1-1 AnnexJ.3)

October , 12th 2023 | Via: Prontubeam | Seen: 1557 times
The following image illustrates how secondary reinforcement behaves in cantilevers under concentrated loads near the support based on the distance from the support. According to EC-2 (1992-1) Annex J.3, depending on this distance, av, it is necessary to provide horizontal reinforcement alone or in combination with vertical reinforcement.

As can be seen, in the calculated example, for distances from av=0.25m (av/h=0.25) up to av=0.60m (av/h=0.60), only longitudinal reinforcement is required. This aligns closely with the EC-2s provisions. The EC-2 suggests that for av/h values greater than 0.5, it is necessary to add vertical stirrups, whereas in our calculation, these are needed for av/h values greater than 0.6. The EC-2 approach appears to be conservative.
Corbels - Secondary reinforcement following EC-2 (1992-1-1 AnnexJ.3)
¿Do you want to publish in Prontubeam? Send us your name, mail and subjet of the article. We will get in touch with you as soon as possible
Full name:
Email adress:
Subjet of the article:
I am not a robot:
Cargando comentarios...
Subscribe: Prontubeam in your mail
I accept the privacy policy
Prontubeam - Verify, calculate, check... the Civil Engineering starts here.
This website has been created by Carlos Corral. More information about cookies click here
The author of this website is not responsible for any possible error in the formulation used. The user has to verify all the results by his own.